进口塑胶料
注:请在右边的搜索栏查找产品

PPS 0205 耐化学,热稳定,易于流动

添加时间:2013-05-17  信息来源:http://www.simibc.com/  作者:苏州希普能塑料
PPS 0205
 
FORTRON® 0205B4 SF3001 NATURAL
FORTRON® 0205P4 SF3001 NATURAL
 
FORTRON 0205 | PPS | Unfilled
 
Description
0205 is an easy flowing unfilled grade. It demonstrates excellent chemical resistance and thermal stability. Intended for compounding with various fillers. Available standard in pellet (0205P4) and powder (0205B4) form.
 
Other Processing
Injection Molding
On injection molding machines with 15-25 D long three-section screws, are usual in the trade, the unreinforced FORTRON is processable. A shut-off nozzle is recommended.
 
Melt temperature 310-320 degC
Mold wall temperature  at least 140 degC
 
A medium injection rate is normally preferred. All mold cavities must be effectively vented.
 
ISO Data Physical properties Value Unit Test Standard
Phys Density 1350 kg/m³ ISO 1183
Mold shrinkage - parallel 1.2 to 1.5 % ISO 294-4
Mold shrinkage - normal 1.5 to 1.8 % ISO 294-4
Water absorption (23℃-sat) 0.02 % ISO 62
Mech Mechanical properties Value Unit Test Standard
Tensile modulus (1mm/min) 4000 MPa ISO 527-2/1A
Tensile stress at break (5mm/min) 66 MPa ISO 527-2/1A
Tensile strain at break (5mm/min) 2 % ISO 527-2/1A
Flexural modulus (23℃) 3900 MPa ISO 178
Flexural stress @ break 130 MPa ISO 178
Unnotched impact str (Izod) @ 23℃ 30 kJ/m² ISO 180/1U
Notched impact strength (Izod) @ 23℃ 2 kJ/m² ISO 180/1A
Rockwell hardness 95 M-Scale ISO 2039-2
Therm Thermal properties Value Unit Test Standard
Melting temperature (10℃/min) 280 ISO 11357-1,-2,-3
Glass transition temperature (10℃/min) 90 ISO 11357-1,-2,-3
DTUL @ 1.8 MPa 115 ISO 75-1/-2
DTUL @ 8.0 MPa 95 ISO 75-1/-2
Coeff.of linear therm. expansion (parallel) 0.53 E-4/℃ ISO 11359-2
Coeff.of linear therm. expansion (normal) 0.52 E-4/℃ ISO 11359-2
Elec Electrical properties Value Unit Test Standard
Volume resistivity 1.00E+09 Ohm*m IEC 60093
Electric strength 17 kV/mm IEC 60243-1
Comparative tracking index CTI 100 - IEC 60112
SpecProd Test specimen production Value Unit Test Standard
Injection molding melt temperature 295 - 330 ISO 294
Injection molding mold temperature 135 - 160 ISO 294
Rheo Rheological Calculation properties Value Unit Test Standard
Specific heat capacity of melt 1830 J/(kg K) Internal
 
Processing
Pre Drying
Necessary low maximum residual moisture content: 0.02%
 
FORTRON should in principle be predried. Because of the necessary low maximum residual moisture content the use of dry air dryers is recommended. The dew point should be =< - 30℃. The time between drying and processing should be as short as possible.
 
For subsequent storage the material should be stored dry in the dryer until processed (<= 60 h).
 
Drying time (h):3-4
Drying temperature (℃):110-120