进口塑胶料
注:请在右边的搜索栏查找产品

PA66 10B140 BK061 含40%矿物增强

添加时间:2013-11-04  信息来源:http://www.simibc.com/  作者:苏州希普能塑料
Minlon PA66 10B140 BK061
Minlon 10B140 BK061 | PA66-MD40 MINERAL REINFORCED NYLON RESIN
 
Product Text
Common features of Minlon® nylon resin include mechanical and physical properties such as high mechanical strength, excellent balance of stiffness /toughness, good high temperature performance, good chemical resistance, paintability, dimensional stability and low warpage.
Grades with improved electrical and flammability properties are available within the Zytel® nylon resin product line. In addition, Minlon® nylon resin is available in different modified and reinforced grades to create a wide range of products with tailored properties for specific processes and end-uses.
 
The good melt stability of Minlon® nylon resin normally enables the recycling of properly handled production waste. If recycling is not possible, DuPont recommends, as the preferred option, incineration with energy recovery (-31kJ/g of base polymer) in appropriately equipped installations. For disposal, local regulations have to be observed.
 
Minlon® nylon resin typically is used in demanding applications in the automotive, electrical, electronic, domestic appliances and construction industries.
 
Minlon® 10B140 BK061 is a 40% mineral reinforced, black polyamide 66 resin for injection molding. It has very low warpage.
 
Injection molding
PREPROCESSING
Drying recommended = Yes, if moisture content of resin exceeds recommended level
Drying temperature = 80℃
Drying time, dehumidified dryer = 2-4 h
Processing moisture content = <0.2 %
 
PROCESSING
Melt temperature optimum = 295℃
Melt temperature range = 285-305℃
Mould temperature optimum = 100℃
Mould temperature range = 70-120℃
Maximum Screw tangential Speed : 0.15 m/s
Flow front speed : 100 mm/s
Hold pressure optimum : 70 MPa
Hold pressure range : 40-100 MPa
Back pressure : low
Hold pressure time : 3 s/mm
Maximum hold-up time : 12 min
 
PROPERTIES
Rheological properties dry / cond Unit Test Standard
Moulding shrinkage,parallel 1.0 / * % ISO 294-4,2577
Moulding shrinkage,normal 1.1 / * % ISO 294-4,2577
Mechanical properties dry / cond Unit Test Standard
Tensile Modulus 10000 / 7080 Mpa ISO 527-1/-2
Stress at break 185 / 125 Mpa ISO 527-1/-2
Strain at break 3 / 6 % ISO 527-1/-2
Tensile creep modulus     ISO 899-1
1h * / 2100 Mpa
1000h * / 1300 Mpa
Charpy impact strength     ISO 179/1eU
23℃ 35 / 60 kj/㎡
-30℃ 25 / 25 kj/㎡
Charpy notched impact strength     ISO 179/1eA
23℃ 3.5 / 4.5 kj/㎡
-30℃ 3.5 / 2 kj/㎡
lzod notched impact strength,23℃ 3.5 / 4 kj/㎡ ISO 180/1A
Thermal properties dry / cond Unit Test Standard
Melting temperature,10℃/min 263 / * ISO 11357-1/-3
Temp. of deflection under load,1.8 MPa 170 / * ISO 75-1/-2
Temp. of deflection under load,0.45 MPa 240 / * ISO 75-1/-2
Vicat softening temperature,50℃/h,50N 245 / * ISO 306
Coeff. of linear therm. expansion,parallel 65 / * E-6/K ISO 11359-1/-2
Coeff. of linear therm. expansion,normal 90 / * E-6/K ISO 11359-1/-2
Flammability dry / cond Unit Test Standard
Burning Behav. at 1.5 mm nom. thickn. HB / * class IEC 60695-11-10
Thickness tested 1.5 / * mm IEC 60695-11-10
UL recognition UL / * - -
Burning Behav. at thickness h HB / * class IEC 60695-11-10
Thickness tested 0.7 / * mm IEC 60695-11-10
Electrical properties dry / cond Unit Test Standard
Relative permittivity,100Hz 4.5 / 9.4 - IEC 60250
Relative permittivity,1MHz 3.9 / 4.5 - IEC 60250
Dissipation factor,100Hz 110 / 2100 E-4 IEC 60250
Dissipation factor,1MHz 230 / 550 E-4 IEC 60250
Volume resistivity - / 1E10 Ohm*m IEC 60093
Surface resistivity * / >1E15 Ohm IEC 60093
Electric strength 40 / - kV/mm IEC 60243-1
Other properties dry / cond Unit Test Standard
Water absorption,2mm 5 / * % Sim. to ISO 62
Humidity absorption,2mm 1.6 / * % Sim. to ISO 62
Density 1500 / - kg/m³ ISO 1183
Material specific properties dry / cond Unit Test Standard
Viscosity number 150 / * cm³/g ISO 307,1157,1628
Rheological calc. properties Value Unit Test Standard
Density of melt 1280 kg/m³ -
Min. mould temperature 70 -
Max. mould temperature 120 -
Min. melt temperature 285 -
Max. melt temperature 305 -

 

 

Chemical Media Resistance

Acids

√ Acetic Acid (5% by mass) (23℃)

√ Citric Acid solution (10% by mass) (23℃)

√ Lactic Acid (10% by mass) (23℃)

× Hydrochloric Acid (36% by mass) (23℃)

× Nitric Acid (40% by mass) (23℃)

× Sulfuric Acid (38% by mass) (23℃)

× Sulfuric Acid (5% by mass) (23℃)

× Chromic Acid solution (40% by mass) (23℃)

 

Bases

× Sodium Hydroxide solution (35% by mass) (23℃)

√ Sodium Hydroxide solution (1% by mass) (23℃)

√ Ammonium Hydroxide solution (10% by mass) (23℃)

 

Alcohols

√ Isopropyl alcohol (23℃)

√ Methanol (23℃)

√ Ethanol (23℃)

 

Hydrocarbons

√ n-Hexane (23℃)

√ Toluene (23℃)

√ iso-Octane (23℃)

 

Ketones

√ Acetone (23℃)

 

Ethers

√ Diethyl ether (23℃)

 

Mineral oils

√ SAE 10W40 multigrade motor oil (23℃)

√ SAE 10W40 multigrade motor oil (130℃)

√ SAE 80/90 hypoid-gear oil (130℃)

√ Insulating Oil (23℃)

 

Standard Fuels

√ ISO 1817 Liquid 1 (60℃)

√ ISO 1817 Liquid 2 (60℃)

√ ISO 1817 Liquid 3 (60℃)

√ ISO 1817 Liquid 4 (60℃)

√ Standard fuel without alcohol (pref. ISO 1817 Liquid C) (23℃)

√ Standard fuel with alcohol (pref. ISO 1817 Liquid 4) (23℃)

√ Diesel fuel (pref. ISO 1817 Liquid F) (23℃)

√ Diesel fuel (pref. ISO 1817 Liquid F) (90℃)

√ Diesel fuel (pref. ISO 1817 Liquid F) (>90℃)

 

Salt solutions

√ Sodium Chloride solution (10% by mass) (23℃)

× Sodium Hypochlorite solution (10% by mass) (23℃)

√ Sodium Carbonate solution (20% by mass) (23℃)

√ Sodium Carbonate solution (2% by mass) (23℃)

× Zinc Chloride solution (50% by mass) (23℃)

 

Other

√ Ethyl Acetate (23℃)

× Hydrogen peroxide (23℃)

√ DOT No. 4 Brake fluid (130℃)

√ Ethylene Glycol (50% by mass) in water (108℃)

√ 1% nonylphenoxy-polyethyleneoxy ethanol in water (23℃)

√ 50% Oleic acid + 50% Olive Oil (23℃)

√ Water (23℃)

× Water (90℃)

× Phenol solution (5% by mass) (23℃)

 

Symbols used:

√ possibly resistant

Defined as: Supplier has sufficient indication that contact with chemical can be potentially accepted under the intended use conditions and expected service life. Criteria for assessment have to be indicated (e.g. surface aspect, volume change, property change).

 

× not recommended - see explanation

Defined as: Not recommended for general use. However, short-term exposure under certain restricted conditions could be acceptable (e.g. fast cleaning with thorough rinsing, spills, wiping, vapor exposure).

联系湘樟塑料